From a dead inverter to a home that makes more power than it uses
Posted on 9 November 2026
Case study, Bouldercombe QLD. A repair call for a 15-year-old solar system became a full replacement: 13.72 kW of new solar and a 30 kWh battery.
- 13.72 kW of solar, 28 panels
- 30 kWh of battery storage
- 115% of the home’s yearly usage made by solar (estimate)
- About $2,800 estimated bill saving a year
What the customer wanted
The owner rang us after a high power bill showed that his old solar system had stopped working. The inverter was stuck in “night mode”. The home runs three water pumps, a pool, air conditioning, fridges and a workshop, and was buying about 29 kWh a day from the grid.
- More solar than the old system gave him
- Enough battery to run the air conditioning overnight
- No tilt frames on the roof
- The old system taken away as part of the price
- The battery kept out of the western sun
What we did
- Found the fault first. Our electrician found a hot joint in the roof isolator and repaired it. The inverter, around 15 years old, still showed a fault, and a further repair came with no guarantee.
- Sized the system from real data. We used the home’s Ergon bill and smart meter interval data, so the system matches how the household uses power.
- Mapped the roof. Two rows of panels would not fit on the north roof. Removing the old system freed the best roof space for 28 panels across the awning and the house, with no tilt frames.
- Gave four options. From adding panels to the existing system, up to a full replacement with a battery. The owner chose to start fresh.
- Found a compliant home for the battery. A battery needs 600 mm clearance from the windows of habitable rooms. That ruled out the old inverter position, so the battery went on an outside wall on the paved area.
The system
- Solar panels: 28 x AIKO Neostar 3S 490 W, all black (13.72 kW), 30-year product and performance warranty
- Inverter: Sigenergy SigenStor 10 kW single-phase energy controller with gateway
- Battery: 3 x SigenStor 10 kWh modules: 30 kWh, about 26 kWh usable, expandable to six modules
- Also included: old system removed and recycled, switchboard upgrade, hot water set up to run on spare solar
The numbers
- 15,200 kWh estimated generation a year
- About 10 years estimated payback
- 10.6 t of CO₂ avoided a year (estimate)
Estimates from the system design for this property, based on its location, roof layout and past electricity use. Actual results depend on weather, usage and tariffs.
On the day

What size system suits your home?
We size every system from your real usage data. Request a quote.